Aiphone has always recognized that there are features and functions that our products don't have. In response we've created a manual detailing the in-field customization of our units to do some of  the more frequently requested functions. Called the "Modification Manual"  and now in it's fifteenth year, it has been an invaluable source of knowledge for in field technicians. It is available free of charge for the first time here.

All modification are in PDF format and are broken down into 5 levels, based on their difficulty:

Level 1 - Easy - Wire Connection Only
Level 2 - Easy/Moderate - Component Connection to External points
Level 3 - Moderate - Removal and replacement of internal Components
Level 4 - Moderate/Hard - Internal connection or component addition
Level 5 - Hard - Circuit Creation and Internal Addition

Please note that modifying a unit will not void it's warranty unless while doing the modification you damage the unit. Aiphone is not liable for any damaged caused during modification. Modifications should only be performed by a person with the skills and knowledge necessary to successfully complete the modification.


Modifications are available for the following systems AP-M, CCS, IE, LEF, LEM, MC-60/4, MP-S, NEM, RAX/RCX, Relays, TD-H, VC-M, YAZ, YKX.
SYSTEM: MODIFICATION: DIFFICULTY LEVEL:
AP-M Zone Paging with the AP-M System 1 - Easy
AP-M External signaling when a sub station calls in 2 - Easy/moderate
AP-M LED monitoring indicator on a sub station 5 - Hard
AP-M Using an LE series sub station with the AP-M system 4 - Moderate/hard
AP-M Extending the LED timing circuit for a longer period of time 4 - Moderate/hard
AP-M Increase the incoming call tone volume from a sub 4 - Moderate/hard
AP-M Long distance communication (2500' max.) 4 - Moderate/hard
AP-M Call tone activation while in monitoring mode 4 - Moderate/hard
AP-M Lamp memory on a single-master AP-M system 3 - Moderate
AP-M Using UL Listed power supplies 4 - Moderate/hard
AP-M Background music through an AP-M system 4 - Moderate/hard
AP-M Tape recorder output 5 - Hard
AP-M Increase communication volume between master stations 4 - Moderate/hard
AP-M Increase receive volume at master station  3 - Moderate
Back to Top
CCS-1A External signaling for the CC-1M 4 - Moderate/hard
Back to Top
IE External signaling of the IE-1AD 2 - Easy/moderate
IE External signaling of the IE-1GD/2AD 2 - Easy/moderate
IE Change IE-1GD or IE-2AD contacts to Normally Closed 3 - Moderate
Back to Top
LEF External signaling device connected to the LEF system 2 - Easy/moderate
LEF Reducing RF interference 4 - Moderate/hard
LEF Prevention of AC power surge and/or lightning damage 2 - Easy/moderate
LEF Adding selective contact terminals ("K" terminals) to LEF-3/3C 4 - Moderate/hard
LEF Eliminate incoming call tone from sub station at master 3 - Moderate
LEF Installing a volume control on an LE series sub station 5 - Hard
LEF LED monitoring indicator on an LE series sub station 5 - Hard
LEF Tape recorder output 5 - Hard
LEF Selective door release on the LEF system 2 - Easy/Moderate
LEF Various relay contacts using the LEF system 2 - Easy/moderate
LEF Single call sub station to receive All Call and BGM 1 - Easy
LEF Separate transmit and receive volume controls 5 - Hard
LEF Increase LED timing circuit 3 - Moderate
LEF LEF system with and without NP-B call button 1 - Easy
LEF Converting the privacy switch to full time privacy mode 4 - Moderate/hard
Back to Top
LEM Dual master system 2 - Easy/Moderate
LEM External signaling for the LEM 2 - Easy/Moderate
LEM External signaling for the LEM-1DL/C 2 - Easy/Moderate
LEM Audio output to a tape recorder 4 - Moderate/Hard
LEM Change LEM-1DL door release contacts to normally closed 3 - Moderate
LEM LEM master with an 8 ohm horn, with and without NP-B 1 - Easy
LEM Eliminate call tone on the LEM-1DL 1 - Easy
Back to Top
MC-60/4A Lightning protection on MC-60/4A system 2 - Easy/Moderate
MC-60/4A Local speaker cutout 4 - Moderate/Hard
MC-60/4A Eliminating paging pre-tone 3 - Moderate
MC-60/4A Relay output while paging 4 - Moderate/Hard
MC-60/4A Using MC-60/4 units in an MC-3 system 1 - Easy
Back to Top
MP-S Dual master system with one remote speaker (MP-1S) 2 - Easy/Moderate
MP-S Dual master connection to remote speakers (MP-3S) 2 - Easy/Moderate
MP-S External signaling for the MP-S system 2 - Easy/Moderate
MP-S LED monitoring indicator on a sub station (MP-1S) 5 - Hard
MP-S LED monitoring indicator on a sub station (MP-3S) 5 - Hard
MP-S Increase incoming call tone volume 3 - Moderate
MP-S Lightning protection on an MP-S system 2 - Easy/Moderate
MP-S Separate control for transmit volume 4 - Moderate/Hard
MP-S Using an LE series sub station with the MP-S system 4 - Moderate/Hard
MP-S Lowering incoming volume while outgoing volume remains high 4 - Moderate/Hard
MP-S Installing an external monitoring speaker 4 - Moderate/Hard
MP-S Hook-up of a tape recorder to an MP-S master 5 - Hard
MP-S Call tone while monitoring (MP-3S) 3 - Moderate
Back to Top
NEM Installing PC-359B with speaker and call button 4 - Moderate/Hard
NEM Dual Master System with selective calling remote stations 4 - Moderate/Hard
NEM LED monitoring indicator on a sub station 5 - Hard
NEM Excluding certain sub stations from All Call and BGM 3 - Moderate
NEM Tape recorder output from an NEM master station 5 - Hard
NEM NEM system with over 40 stations and BGM 2 - Easy/Moderate
NEM Lengthen time between rings on master (incoming call) 3 - Moderate
NEM Elimination of pretone, or Lengthening of pretone. 3 - Moderate
NEM

Timer/Clock relay to activate tone generator through NEM

2 - Easy/Moderate
NEM Call tone annunciation during monitoring mode 3 - Moderate
NEM Using LE series sub stations with the PC-359B on NEM system 4 - Moderate/Hard
NEM Increase pretone volume to sub station 3 - Moderate
NEM External signaling of an NA-T/A handset sub station 4 - Moderate/Hard
NEM Call initiation from NA sub when an NA-T/A is also used 4 - Moderate/Hard
NEM Call extension on the NEM system 2 - Easy/Moderate
NEM Extra closure from sub station when call is placed 2 - Easy/Moderate
NEM External amplifier for louder All Call volume 2 - Easy/Moderate
Back to Top
RAX/RCX External speaker for louder volume in receive mode 3 - Moderate
Back to Top
RELAY Modify RY-PA for normally closed contacts 3 - Moderate
RELAY Modify TAR-3 for momentary activation 3 - Moderate
Back to Top
TD-H/B Door/Gate communication through a 70V horn 2 - Easy/Moderate
TD-H/B Third call tone from DE-UR 3 - Moderate
TD-H/B Lower the call tone frequency from a door station 3 - Moderate
TD-H/B External signaling from door station(s) 2 - Easy/Moderate
TD-H/B Installing a call tone volume control 4 - Moderate/Hard
TD-H/B Change the call-in time from DE-UR to TD-H/B phones 3 - Moderate
TD-H/B Lower the call tone volume 3 - Moderate
TD-H/B Smoother call tone 4 - Moderate/Hard
TD-H/B TD-H/B with multiple paging zones and All Page 1 - Easy
TD-H/B LED call indicator in place of call tone 4 - Moderate/Hard
TD-H/B Eliminate pre-tone when paging is activated 3 - Moderate
TD-H/B TD-1H with off-hook ringing 4 - Moderate/Hard
TD-H/B Dry closure while paging 4 - Moderate/Hard
TD-H/B Audio output to tape recorder

4 - Moderate/Hard

TD-H/B Dry contact while handset is off-hook 4 - Moderate/Hard
TD-H/B TD-H/B System with one button ringing to all handsets 2 - Easy/Moderate
TD-H/B Using TD-H handsets with TB Series handsets 3 - Moderate
Back to Top
VC-M Using four wires with the VC-M system 2 - Easy/Moderate
VC-M Using VC-K handsets with an existing VAM system 2 - Easy/Moderate
VC-M Increase call tone frequency to VC-K 3 - Moderate
VC-M Lower the call tone volume heard at VC-K 4 - Moderate/Hard
VC-M Elimination of call tone and addition of external door chime 3 - Moderate
VC-M Dry contact when any VC-K is off-hook 4 - Moderate/Hard
Back to Top
YAZ External signaling for the YAZ-90-3 2 - Easy/Moderate
Back to Top
YKX External speaker for louder volume in receive mode 3 - Moderate