Securitex handicap help system

Medical handicap hardware technology design division

Securitex HCT-A1SR

Securitex Handicap Toilet Emergency System

Securitex Handicap Panic Alarm System

Securitex Distress Activation System

Securitex Medical Alert System


DESCRIPTION:

The SECURITEX/Aiphone HCT-A1SR Series uses the NHR-7A Handicap Bathroom-Toilet Emergency Call Station for the Communi-Care or localize emergency siren system provides call annunciation from a bathroom associated with a patient station (NH-1SA or NH-2SA or standalone localized system). It also provides call annunciation from a common area restroom or staff call location when used with the NHR-3TS common area call station. If the NHR-7A is use as standalone on Securitex HCT-A1SR handicap toilet system it will act as a emergency pull cord to activate the control and sound off the local siren. The NHR-7A is constructed with a rugged 1-piece fire-retardant ABS plastic faceplate and is waterproof for use in bathrooms. Switch can be pressed down to call or activated with the pull-cord.

OPERATION:

A call from the bathroom pull-cord will annunciate an urgent tone and flashing LED on the master station if used with NH-1SA. indicating the location of the call. The duty station will receive the call tone and flashing LED, but does not indicate the calling location. When the NHR-7A is connected to a common area call station, the associated lamp on the NHR-3TS will flash, and the location will be annunciated on the master station. The call must be cancelled at the calling location by moving the call switch to the upward position.

If the NHR-7A is use as standalone on Securitex HCT-A1SR handicap toilet system it will act as a emergency pull cord to activate the controller and sound off the local siren with blinker light.

HCT-A1SR wireless

The HCT-A1SR-RF can also be incorporated with a wireless receiver and transmitter so that disable person will not need to use the pull cord to activate the system in an emergency.

HCT-A1SR GSM

The HCT-A1SR-GSM can also be incorporated with a GSM-SMS system so that when the system is activated it will sent out distress signal to the care giver or central monitoring station. 

ARCHITECTS/ENGINEERS SPECIFICATIONS:

Bathroom/urgent call station shall be Aiphone model NHR-7A, equipped with locking vertical slide call switch, nylon cord with pendant and LED “call placed” indicator. Call station shall be waterproof, constructed with 1-piece rugged fire-retardant ABS plastic. Nylon cord shall be durable and able to activate a call-in signal by pulling the cord in any direction. NHR-7A shall be used to place an urgent call associated with the NH-1SA or NH-2SA patient station or NHR-3TS common area call station. Call shall be reset only at the calling station by moving the call switch to the upward position. Wiring shall be 3 conductors, run from associated patient station or common area call station. Cable size greater than 22AWG shall not be requires. Unit shall flush mount into a standard 1-gang box. Equipment shall be UL 1069 listed.

CONTROLS AND INDICATORS:

• Vertical slide switch

• Nylon cord with pendant

• LED “call placed” indicator

SPECIFICATIONS:

Power source         : From call station or not requires if use as standalone pull cord switch.

Capacity                 : As many as required per call station

Mounting                 : 1-gang box, UL listed

Wiring                     : 3 conductors to associated call station or 2 conductor for local system use Aiphone #862208 for color-code matching, or Aiphone #822203.

Material                  : High impact ABS fire-retardant plastic

Pull cord                 : Nylon cord

Color                       : White, with red call switch

Dimensions            : (H x W x D): 4-1/2” x 2-13/16” x 1-3/4”

Certification           : UL 1069 Listed, C-UL Canadian Standard C22.2

Changes                 : Product specification and designed is subject to change without notice

Securitex Handicap toilet emergency system currently being use at:

a.    Kallang Paya Lebar Expressway ventilation building (KPE C423 Project) Ventilation Building B Mountbatten Road VBB

b.    Division headquarters cum fire station at Yishun For Singapore Civil Defense Force

Designed, manufactured, fabricated, distributed and marketed by SECURITEX