Securitex Anti Intrusion Division Active IR (infrared) perimeter protections |
2PH150A (1 double beam) |
|
Technical specifications |
|
Power supply | 10.5-28 Vdc |
Absorption | 55 mA |
Relay Intervention time | from 50 to 700 ms |
Detection mode | Interruption of both beams |
Output relay | 1 alarm N.O. /N.C. - Range 0.2 A -30 VDC 1 tamper N.O. /N.C. - Range 0.2 A -30 VDC |
Adjustment angle | horizontal 0 - 180° - vertical ± 10° |
Cable diameter | 2 x 0.75 mm2 for 5 m - 2 x 2.5 mm2 for 150 m |
Signal Cable diameter | 2 x 0.22 mm2 for 150 m of cable |
Protection rating | IP 55 |
Operating temperature | from -20° to +55° C |
Dimensions and weight | 100 x 247 x 100 mm - 1800 g |
2PH60C (1 double beam) |
|
Technical specifications |
|
Power supply | 10.5-28 Vdc |
Absorption | 45 mA |
Relay Intervention time | from 50 to 700 ms |
Detection mode | interruption of both beams |
Output relay | 1 alarm N.O. /N.C. - Range 0.2 A -30 VDC 1 tamper N.O. /N.C. - Range 0.2 A -30 VDC |
Adjustment angle | horizontal 0 - 180° - vertical ± 10° |
Cable diameter Power supply | 2 x 0.75 mm2 for 5 m - 2 x 2.5 mm2 for 150 m |
Signal Cable diameter | 2 x 0.22 mm2 for 150 m of cable |
Protection rating | IP 55 |
Operating temperature | from -20° to +55° C |
Dimensions and weight | 75 x 180 x 75 mm - 1100 g |
4PH200A (2 double beams) |
|
Technical specifications | |
Power supply | 10.5-28 Vdc |
Absorption | 77 mA |
Relay Intervention time | from 50 to 700 ms |
Detection mode | Interruption of the 4 beams |
Output relay | 1 alarm N.O. /N.C. - Range 0.2 A -30 VDC 1 disqualification device N.O. /N.C. - Range 0.2 A -30 VDC 1 tamper N.O. /N.C. - Range 0.2 A -30 VDC |
Adjustment angle | horizontal 0 - 180° - vertical ± 10° |
Cable diameter Power supply | 2 x 0.75 mm2 for 5 m - 2 x 2.5 mm2 for 150 m |
Signal Cable diameter | 2 x 0.22 mm2 for 150 m of cable |
Protection rating | IP 55 |
Operating temperature | from -20° to +55° C |
Dimensions and weight | 100 x 390 x 100 mm - 3700 g |
BIRAY200S (2 beams) |
|
Technical specifications | |
Power supply | 12 Vac/dc |
Thermo stating power supply | 12-24 Vac/dc |
Nominal Absorption | 75 mA |
Absorption with thermo stating | 340 mA |
Detection mode | Interruption of the 4 beams |
Relay Intervention time | from 50 to 700 ms |
Disqualification device reply time | 1 minute |
Alarm duration | 4 s |
Output relay | 1 alarm - Range 30 VDC - 500 mA 1 tamper - Range 30 VDC - 50 mA |
Power supply Cable diameter | 2 x 0.75 mm2 per 5 m - 2 x 2.5 mm2 per 150 m |
Signal Cable diameter | 2 x 0.22 mm2 for 150 m of cable |
Protection rating | IP 33 - IP 65 in INFRA column |
Operating temperature | da -20° a +55° C |
Dimensions and weight | 70 x 360 x 600 mm - 1200 g |
IOR5MS (1 beam) |
|
Technical specifications | |
Power supply | 12-24 Vac/dc |
Absorption | 60 mA |
Wavelength I.R. | 950 nm |
Relay Intervention time | da 30 a 300 ms |
Alarm duration | 4 s |
Output relay | 1 N.C. - portata 1 A - 24 Vdc |
Adjustment angle | horizontal 0 - 180° - vertical ± 10° |
Cable diameter Power supply | 2 x 0.75 mm2 for 5 m - 2 x 2.5 mm2 for 150 m |
Signal Cable diameter | 2 x 0.22 mm2 for 150 m of cable |
Protection rating | IP 55 |
Operating temperature | from -20° to +55° C |
Dimensions and weight | 127 x 60 x 55 mm - 410 g |
KINFRA500 (2 beams) |
|
Kit consisting of: |
|
Technical specifications | |
Power supply: | 12-24 Vac/dc |
Absorption: | 120 mA |
Wavelength I.R.: | 950 nm |
Relay Intervention time: | from 30 to 300 ms |
Alarm duration: | 4 s |
Output relay: | 2 N.C. - Range 1 A - 24 VDC |
Adjustment angle: | horizontal 0 - 180° - vertical ± 10°° |
Power supply Cable diameter: | 2 x 0.75 mm2 for 5 m - 2 x 2.5 mm2 for 150 m |
Signal Cable diameter: | 2 x 0.22 mm2 for 150 m of cable |
Protection rating: | IP 55 |
Operating temperature: | from -20° to +55° C |
Dimensions and weight: | 100 x 500 x 100 mm - 4000 g |
To contact our sales and technical department please call 65-67852171 or email: sales@securitex.com.sg |
Securitex Electronic
Systems Engineering
(Date Created: 03 November 2008) |