Securitex Marine Specialized Equipment Development Division
Securitex
Ship, Vessel, Ocean Liners and Super tankers security division
In today security
threads around the world, Vessel, Ships, Ocean liners and Super tankers are
target that pirates and terrorist are looking to strike. At Securitex we
have designed a system that allows the Onboard Security Personnel in the
ship to do regular inspection and check round the clock without fail using
Securitex DMAS. What is Securitex DMAS. DMAS is
a programmable countdown timer system that is preprogrammed at a certain
time interval. This timer will countdown and upon time –up the Siren
connected to the DMAS will sound reminding the Security personnel to go for
their rounds. (The more complex system can be interface to system than can
activate distress signal and event reporting etc OPTIONAL)
System works
as follows:
The system is preset
at default 15 minute. Upon the 15 minute is up the timer 1 (T1) will kick in
and activate the relay to trigger the (baby siren) to be provided by others.
If the monitoring personnel do not reset the baby siren after say 10 minute,
the second built-in timer (T2) will cut in and activate the 2nd relays to
trigger the (master horn siren) (also provided by others) In the event the
baby siren trigger and the monitoring personnel reset it, the system will
automatically reset to 15 minute and re-count again. If after 10 minute is
up and the baby siren is not reset the master horn siren will trigger, in
this instance to reset the system just press any reset button and the system
will reset back to the original preset timing again.
Securitex Dead
Man Alarm System (DMAS Ver.2SER) detail system
operation
When power is turn
on the DMAS will activate with T1 indicate 0015 (15 minute). Immediately the
T1 timer will count down from 0015 to 0000. At 0000/9999 the T1 (LED will
turn on and R1 will activate this will trigger the Alarm 1 (Baby siren) if
at anytime before the T1 time is up and the reset button is press, the T1
will reset back to 15 minute and continue the T1 count down as indicated
above. However if the reset button is not press T2 board will activate and
display 0010 (10 minute) and start counting down to 0000/9999. At this point
the T2 (LED will turn on and R2 will activate this will trigger the Alarm 2
(Master horn siren). Till the reset button is press, both alarms will
continue to sound.
To change the
timing for the Timer 1 (T1)
-
Press the (T1) SW1 for 1
second (the first digit of the 4 digit 7 segment display will blink).
-
Press SW2 to move the digit
forward to the digit you want to change.
-
Press SW3 to decrease the
digit and press SW4 to increase the digit
-
Exit programming by
pressing SW1 after time set.
Example: 0015
indicated 15 minute
To change the
timing for the Timer 2 (T2)
Press and hold Button 6 (BU 6).
(T2) time board will be lighted up and indicate
0010.
Continue to hold Button 6 when programming (T2)
-
Press the (T1) SW1 for 1
second (the first digit of the 4 digit 7 segment display will blink).
-
Press SW2 to move the digit
forward to the digit you want to change.
-
Press SW3 to decrease the
digit and press SW4 to increase the digit
-
Exit programming by
pressing SW1 after time set.
Example: 0010
indicated 10 minute
Note the T1 and
T2 board.
When the Time out is
up and the system is not reset, the T1 and T2 board will switch to 0000.
After 1 minute the T1 and T2 will switch to 9999 and count down from 9999 to
9998 to 9997 etc…… this is normal and the figure indicate the total time the
siren had sounded.
The Default setting
for:
[T1 is 15 minute]
[T2 is 10 minute]
T2 will only start
counting down if T1 is not reset after 15 minute
Technical Specifications |
Supply Voltage |
12 VDC |
Supply Current |
40mA to 80mA |
Relay Switching Capability |
Up to 12 A at 28V |
Physical Size of Single PCB
Board |
75mm x 51mmx 20mmm |
Gross dimension
|
250mm x 175mm x 75mm |